9
• Interface - Port 1
- RS232 GTxD, RxD for data stream, no flow control
- RS232 (RTS/CTS) GTxD, RxD for data stream,
RTS/CTS for flow control
• Interface - Port 2: TheAuto Detect feature will detect
the connected serial device's interface as RS-422 or
RS-485 automatically
- RS485 (Half duplex): Half duplex RS-485 interface,
RTS for driver enable/disable
- RS422 (Full duplex): Full duplex RS-422 interface
• Baudrate- Port 1: 300 ~ 460800 bps
• Baudrate- Port 2: 300 ~ 115200 bps
• Parity: None, Even, Odd, Space, Mark
• Data Bits: 5, 6, 7, 8
• Stop Bit: 1 or 2
• Force off-line time: Setting for off-line duration
when there is no data input. The parameter can be
from "0 to 255" and the time unit is "Minute"
• Packet Collect Time
Packet collecting period setup of the device serial
port's Tx and Rx. It can be 0 to 999, and the time unit
is "mSec"
Figure 9
NOTE: There's no function for DI/DO. Skip Digital
I/O Port 1/2 section. See Figure 9.