11
4. Press A to Auto configure.
5. Press Y to accept the configuration.
6. Press ESC to reboot.
7. Continue with Fdisk and Format steps as if you
were installing a conventional hard drive.
Rebuilding a Failed RAID 0+1 Set
The steps below will guide you in rebuilding a failed
Mirrored-Stripe set.
1. Replace the failed drive with one of identical size or
of larger capacity.
Note: It is recommended to replace the bad drive
with an identical drive, or with a drive of the same
make. In all cases, the replacement drive must be of
equal or larger capacity than the bad drive.
2. Start the computer and during boot press F3, when
prompted, to enter the RAID BIOS.
3. Press F3 to assign a Spare drive.
4. Press the number corresponding to the new drive.
5. When asked Are You Sure? Press Y to accept.
6. Press ESC to exit the RAID BIOS and reboot the
computer.
Note: Ignore the error message displayed by the
RAID BIOS and continue booting. The mirror will
rebuild automatically.
Comentários a estes Manuais